Purpose and area of application
The steam turbine installation is used at industrial heating boiler-houses and thermal power stations and is designed for using steam potential which is being lost from throttling
Main advantages
- power options at individual customer requirements;
- low specific cost ($250 per kW against $400 per kW with Russian analogues and $500 per kW with foreign analogues);
- simple control;
- low specific metal consumption;
- small overall dimensions increasing the turbine mobility;
- microprocessor-based protection and automatics systems;
- fire safety.
Technical data
N
|
Characteristics
|
Turbine types
|
Ð-0.25 |
Ð-0.35 |
Ð-0.65 |
Ð-1.0 |
1 |
Power at generator clips at cos j =0,8 |
250 |
350 |
650 |
1000 |
2 |
Rotor turning frequency:
- turbine, s-1 (rev/min)
- generator, s-1(rev/min) |
50(3000)
50(3000) |
50(3000)
50(3000) |
25(1500)
25(1500) |
25(1500)
25(1500) |
3 |
Working steam parameters
|
|
|
|
|
|
before turbine: |
|
|
|
|
|
- pressure, MPa
- temperature, °Ñ |
1.3
191 |
3.9
440 |
1.3
191 |
1.3
191 |
|
outside turbine: |
|
|
|
|
|
- pressure, MPa |
0.37 (0,1…0,4) |
1.1 (1,0... 1,3) |
0.2 (0,1... 0,4) |
0.22 (0,1…0,4) |
4 |
Efficiency coefficient of power output |
0.55 |
0.51 |
0.57 |
0.56 |
5 |
Working steam consumption kg/s (t/hour) |
1.8 (6.5) |
1.87 (6.7) |
3.6 (13.0) |
5.8 (21) |
6 |
Available heat difference, kJ/kg |
251.2 |
344 |
317.4 |
307 |
7 |
Generator type |
4ÀÍ315 |
Turbine drive |
Turbine drive |
asynchronous |
8 |
Installation weight, dry, kg |
1500 |
2500 |
3200 |
6000 |
9 |
Service life, years |
30 |
35 |
35 |
30 |
10 |
Overall dimensions, mm
- length
- width
- height |
1191
1230
945 |
1191
1230
945 |
1450
1630
1050 |
1450
1630
1050 |
|

|